PMA-XX Environmental specifications: Difference between revisions
No edit summary |
No edit summary |
||
Line 6: | Line 6: | ||
| | ||
[[File:PMA-XX_REAR_Connections|border|center | [[File:PMA-XX_REAR_Connections|border|center|PMA-XX_REAR_Connections.png]] | ||
| | ||
Line 63: | Line 63: | ||
Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. <span style="background-color:#FFFF00">Copper transceivers are not supported</span>. One or more of these ports must be connected to a SPAN or TAP. Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.<br/> | Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. <span style="background-color:#FFFF00">Copper transceivers are not supported</span>. One or more of these ports must be connected to a SPAN or TAP. Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.<br/> | ||
[[Category:Pages with broken file links]] |
Revision as of 12:41, 28 May 2020
Network connections (appliance rear view)
This picture shows the minimal set of ports that must be connected.
Located on the server base:
IP management interface (iDRAC): 1x 1000BASE-T
Management port (MGT): 2x 1000BASE-T
Optional monitor port (MON): 2x 1000BASE-T
System dimensions
Width: 430.0mm (19 inch)
Hight: 86.8mm (2U)
Depth: 715.5mm
Weight
33.1kg
PSU specifications
PSU (Power): 2x 1100W (IEC320 C14 connector)
Maximum heat dissipation: 4100BTU/h
Frequency: 50Hz
Voltage: 240V AC
Maximum current: 6.5A
Power based on observation: 500W maximum, 350W average (both PSU powered)
Network connections
Located on the server's motherboard:
Out-of-band management and virtual console (iDRAC): 1x 1000BASE-T
Management (MGT): 2x 1000BASE-T and 2x 10GBASE-T. At least one of these ports must be connected to a switch port.
Located on the ASI Accelerator NIC:
Monitor (MON): 4x SFP+. These slots are empty and must be equipped with fiber optic transceivers. Copper transceivers are not supported. One or more of these ports must be connected to a SPAN or TAP. Ports are numbered from right to left, starting at number 3 then 4, 5 and 6.