PMA-XX Environmental specifications: Difference between revisions
No edit summary |
No edit summary |
||
Line 26: | Line 26: | ||
Management ports (<span style="background-color:#F0FFFF;">MGT1</span> & <span style="background-color:#F0FFFF;">MGT2</span>): 2x 1000BASE-T | Management ports (<span style="background-color:#F0FFFF;">MGT1</span> & <span style="background-color:#F0FFFF;">MGT2</span>): 2x 1000BASE-T | ||
'' | *''These ports provide a redundant connection with the network'' | ||
*''At least one of these ports must be connected'' | |||
Monitor port (<span style="background-color:#FFFFE0;">MON1</span> & <span style="background-color:#FFFFE0;">MON2</span>): 2x 1000BASE-T | Monitor port (<span style="background-color:#FFFFE0;">MON1</span> & <span style="background-color:#FFFFE0;">MON2</span>): 2x 1000BASE-T | ||
''The purpose of these monitor ports will depend on the software running on de appliance | *''The purpose of these monitor ports will depend on the software running on de appliance '' | ||
*''On PMA-XX with packet collector, these ports will be two independent packet ingress ports'' | |||
*''On PMA-XX with flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network'' | |||
*''At least one of these ports must be connected'' | |||
| |
Revision as of 07:44, 31 August 2020
Introduction
These specifications are valid for both PMA-65, PMA-85 appliances.
Solution
Appliance rear view
This picture shows the connection on the rear of the appliance.
Network connections
IP remote management interface (iDRAC): 1x 1000BASE-T
Management ports (MGT1 & MGT2): 2x 1000BASE-T
- These ports provide a redundant connection with the network
- At least one of these ports must be connected
Monitor port (MON1 & MON2): 2x 1000BASE-T
- The purpose of these monitor ports will depend on the software running on de appliance
- On PMA-XX with packet collector, these ports will be two independent packet ingress ports
- On PMA-XX with flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network
- At least one of these ports must be connected
Dimensions
Width: 434mm (19" sliding rails)
Hight: 42.4mm (1U)
Depth: 715mm
Weight
17.6kg (without disk)
Power
PSU: 2x 550W (IEC320 C14 connector)
Frequency: 50/60Hz
Voltage: 100-240V AC
Maximum current: 3.5A
Measured 7-day average power: PMA-65: 90W / PMA-85: 203W
Heating
Maximum heat dissipation: 2559BTU/h
Noise
A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA
Environment
Storage: -40°C to 65°C and 5% to 95% RH
Operation: 10°C to 35°C and 10% to 80% RH