ISNG model 6695 Connections: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 10: Line 10:
==== Mandatory connections located on the appliance motherboard: ====
==== Mandatory connections located on the appliance motherboard: ====


*Management interfaces (MGT) from left to right: .  Only one of these ports must be connected to the network (InfiniStream does not support redundant connections).  By default, the first management port from the left is used as the appliance's management interface.
*Management interface (Eth0):  This is a 1000BASE-T Ethernet interface.  Attention, only this port (Eth0) must be connected to the network (InfiniStream does not support redundant connections).    
*Dedicated remote management modume (iDRAC).  This is a 1000BASE-T Ethernet interface.  It is recommended to connect this interface to the network to allow out-of-band management of the appliance.  
*Dedicated remote management module (RMM).  This is a 1000BASE-T Ethernet interface.  It is recommended to connect this interface to the network to allow out-of-band management of the appliance.  


==== Mandatory connections located on the NETSCOUT ASI Accelerator NIC: ====
==== Mandatory connections located on the NETSCOUT ASI Accelerator NIC: ====
Line 19: Line 19:
==== Optional connections located on the appliance motherboard (primarily used for KVM): ====
==== Optional connections located on the appliance motherboard (primarily used for KVM): ====


*Serial Console: 115200 baud, 8N1   
*Serial Console 115200 baud, 8N1   
*4x USB 3  
*4x USB 3  
*VGA  
*VGA  
*Eth 1 (disabled)
*Network interface Eth1 (1000BASE-T, disabled)

Revision as of 15:56, 18 July 2022

Network connections (appliance rear view)

 

IS-06695-ZSJAB-J_RV.png
IS-06695-ZSJAB-J_RV.png

 

Mandatory connections located on the appliance motherboard:

  • Management interface (Eth0):  This is a 1000BASE-T Ethernet interface.  Attention, only this port (Eth0) must be connected to the network (InfiniStream does not support redundant connections).  
  • Dedicated remote management module (RMM).  This is a 1000BASE-T Ethernet interface.  It is recommended to connect this interface to the network to allow out-of-band management of the appliance.

Mandatory connections located on the NETSCOUT ASI Accelerator NIC:

  • Monitor interfaces (MON): 4x SFP+ slots. These slots are empty and are to be equipped with compatible fiber optic transceivers.  Attention: copper transceivers are not supported.  At least one of these ports must be connected to a SPAN or TAP output.  These ports are named (from top to bottom) if3, if4, if5 and if6.

Optional connections located on the appliance motherboard (primarily used for KVM):

  • Serial Console 115200 baud, 8N1 
  • 4x USB 3
  • VGA
  • Network interface Eth1 (1000BASE-T, disabled)