Connecting a passive TAP: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 34: Line 34:
==== Y-cable ====
==== Y-cable ====


The two fibers of the duplex LC-LC output of the TAP - indicated with "monitor" - are both used for transmission.
The two fibers of the duplex LC-LC output of the TAP - indicated with "monitor 1A and 1B" - are used for transmission.


To connect to the NETSCOUT Accelerator NIC, you need a LC-LC-duplex to 2x LC-simplex fan-out cable. It is very simple to make a cable like this from a standard (zip) fiber optic patch cord:
To connect to the NETSCOUT Accelerator NIC, you need a LC-LC-duplex to 2x LC-simplex Y-cable.  It is very simple to make a cable like this from a standard duplex fiber optic patch cord:


 
 
Line 58: Line 58:
=== Port aggregation ===
=== Port aggregation ===


An aggregate must be created from the two connected ports. Ask your COMCERT Engineer to configure a Port Aggregate or read the Agent Configuration Utility for CDM/ASI Administration Guide carefully for details on how to create a Port Aggregate.
An aggregate must be created from the two connected ports. Ask your COMCERT Engineer to configure a Port Aggregate or read the Agent Configuration Utility for CDM/ASI Administration Guide carefully for details on how to create a Port Aggregate.

Revision as of 16:35, 23 December 2022

Introduction

Passive Fiber Optic TAPs require little or no configuration. While cabling the network - and site ports is straight forward, the cabling between the TAP output and the NETSCOUT Accelerator NIC is somewhat special.

 

Solution

 

 

 

 

LC SM/MM HD Fiber TAP

The label on the tap indicated where the light should arrive (Rx) and where it will be transmitted (Tx). 

TAP internal wiring:

 

TAPInternalCabling.png
TAPInternalCabling.png

Y-cable

The two fibers of the duplex LC-LC output of the TAP - indicated with "monitor 1A and 1B" - are used for transmission.

To connect to the NETSCOUT Accelerator NIC, you need a LC-LC-duplex to 2x LC-simplex Y-cable.  It is very simple to make a cable like this from a standard duplex fiber optic patch cord:

 

LCLCFanOut.jpg
LCLCFanOut.jpg

 

Connecting the TAP to the NETSCOUT Accelerator NIC

Both LC-simplex connectors of the Y-cable must be connected to the input (RX) of two SFP/SFP+ ports on the NETSCOUT Accelerator NIC on the back of the appliance.  The ports are numberd from top to bottom.  Some appliances (like the PMA-2XX) have the card rotated 90° clockwise.  It is recommeded to start with the lowest port numbers.

The following picture is showing the TAP - situated on top of the appliance - while the output is connected with a Y-cable to the first and second interface (SFP+) of the NETSCOUT Accelerator NIC.  The TAP is not yet brought in line.

 

TAPConnectNIC.jpg
TAPConnectNIC.jpg

 

Port aggregation

An aggregate must be created from the two connected ports. Ask your COMCERT Engineer to configure a Port Aggregate or read the Agent Configuration Utility for CDM/ASI Administration Guide carefully for details on how to create a Port Aggregate.