ISNG model 6695 Connections: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
| | ||
=== Required connections (as | === Required connections (as pictured) === | ||
==== Network interfaces located on the SUPERMICRO Server motherboard: ==== | ==== Network interfaces located on the SUPERMICRO Server motherboard: ==== |
Revision as of 15:49, 18 March 2023
Network connections (server rear view)
Required connections (as pictured)
Network interfaces located on the SUPERMICRO Server motherboard:
- Management network interface Eth0 (10GBASE-T).
- Remote Management Module RMM interface (1000GBASE-T).
Network interfaces located on the NETSCOUT ASI Accelerator NIC:
- Monitor interfaces (SFP+). These docks are empty and must be equipped with compatible 10G SFP+ fiber optic transceivers. Copper transceivers are not supported. At least one of these ports should be connected to a SPAN or TAP output. These ports are system named from top to bottom if3, if4, if5 and if6.
Optional connections
Optional connections located on the appliance motherboard:
- Management network interface Eth1 (10GBASE-T) for redundancy
- Serial Console 57600 baud, 8N1
- 4x USB 3
- VGA
Environment specifications
Power supply: dual auto-ranging hot-swappable, redundant power supplies. 1200W: 200-240VAC, 8.5-7A, 50–60 Hz.
Measured 1h AVG power consumption: 1000W or 3412BTU/h
Dimensions: 3U Rack Mount (static rails)
Weight without rails: 27kg