PMA-XX Environmental specifications: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 66: Line 66:
Maximum heat dissipation: 2559BTU/h
Maximum heat dissipation: 2559BTU/h


===   ===
 


=== Noise ===
=== Noise ===
Line 72: Line 72:
A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA
A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA


===   ===
 


=== Environment ===
=== Environment ===

Revision as of 07:25, 4 June 2020

Introduction

These specifications are valid for both PMA-65, PMA-85 appliances.

 

Solution

Appliance rear view

This picture shows the connection on the rear of the appliance.

 

PMAXXREARConnections.png
PMAXXREARConnections.png

 

 

Network connections

IP remote management interface (iDRAC): 1x 1000BASE-T

Management ports (MGT1 & MGT2): 2x 1000BASE-T

These two management ports form a team, enabling a redundant uplink to the network

Optional monitor port (MON1 & MON2): 2x 1000BASE-T

 

Dimensions

Width: 434mm (19" sliding rails)

Hight: 42.4mm (1U)

Depth: 715mm

 

Weight

17.6kg (without disk)

 

Power

PSU: 2x 550W (with IEC320 C14 connector)

Frequency: 50/60Hz

Voltage: 100-240V AC

Maximum current: 3.5A

Measured 7-day average power: PMA-65: 90W / PMA-85: 203W

 

Heating:

Maximum heat dissipation: 2559BTU/h

 

Noise

A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA

 

Environment

Storage: -40°C to 65°C and 5% to 95% RH

Operation: 10°C to 35°C and 10% to 80% RH