PMA-XX Environmental specifications: Difference between revisions

From wiki.comcert.com
Jump to navigation Jump to search
No edit summary
No edit summary
Line 26: Line 26:
Management ports (<span style="background-color:#F0FFFF;">MGT1</span> & <span style="background-color:#F0FFFF;">MGT2</span>): 2x 1000BASE-T
Management ports (<span style="background-color:#F0FFFF;">MGT1</span> & <span style="background-color:#F0FFFF;">MGT2</span>): 2x 1000BASE-T


''The management ports allow a redundant connection with the network.&nbsp; At least one of these ports must be connected.''
*''These&nbsp;ports provide a redundant connection with the network''
*''At least one of these ports must be connected''  


Monitor port (<span style="background-color:#FFFFE0;">MON1</span> & <span style="background-color:#FFFFE0;">MON2</span>): 2x 1000BASE-T
Monitor port (<span style="background-color:#FFFFE0;">MON1</span> & <span style="background-color:#FFFFE0;">MON2</span>): 2x 1000BASE-T


''The purpose of these monitor ports will depend on the software running on de appliance.''
*''The purpose of these monitor ports will depend on the software running on de appliance&nbsp;&nbsp;''
*''On PMA-XX with packet collector, these ports will be two independent&nbsp;packet ingress ports''
*''On PMA-XX with flow collector, these ports will be assigned to the flow collector and&nbsp;provide a redundant connection with the network''
*''At least one of these ports must be connected''  


&nbsp;
&nbsp;

Revision as of 07:44, 31 August 2020

Introduction

These specifications are valid for both PMA-65, PMA-85 appliances.

 

Solution

Appliance rear view

This picture shows the connection on the rear of the appliance.

 

PMAXXREARConnections.png
PMAXXREARConnections.png

 

 

Network connections

IP remote management interface (iDRAC): 1x 1000BASE-T

Management ports (MGT1 & MGT2): 2x 1000BASE-T

  • These ports provide a redundant connection with the network
  • At least one of these ports must be connected

Monitor port (MON1 & MON2): 2x 1000BASE-T

  • The purpose of these monitor ports will depend on the software running on de appliance  
  • On PMA-XX with packet collector, these ports will be two independent packet ingress ports
  • On PMA-XX with flow collector, these ports will be assigned to the flow collector and provide a redundant connection with the network
  • At least one of these ports must be connected

 

Dimensions

Width: 434mm (19" sliding rails)

Hight: 42.4mm (1U)

Depth: 715mm

 

Weight

17.6kg (without disk)

 

Power

PSU: 2x 550W (IEC320 C14 connector)

Frequency: 50/60Hz

Voltage: 100-240V AC

Maximum current: 3.5A

Measured 7-day average power: PMA-65: 90W / PMA-85: 203W

 

Heating

Maximum heat dissipation: 2559BTU/h

 

Noise

A-weighted noise emissions in accordance with ISO 9296 (tested in accordance with ISO 7779): 53dBA

 

Environment

Storage: -40°C to 65°C and 5% to 95% RH

Operation: 10°C to 35°C and 10% to 80% RH