The appliance management (MGT) and iDRAC interface comes pre configured with the following IP parameters. | The appliance management (MGT) and out-of-band (iDRAC) interface comes pre configured with the following IP parameters. | ||
{| border="1" cellpadding="1" cellspacing="1" style="width: 500px;" | {| border="1" cellpadding="1" cellspacing="1" style="width: 500px;" | ||
Line 48: | Line 48: | ||
| 192.168.1.1 | | 192.168.1.1 | ||
|} | |} | ||
To access the appliance either by its management interface of out-of-band interface, use a laptop with a static IP address in the same IP subnet as the respective interface and a standard four-pair twisted-pair cable. The management interface is only accessible using the ssh protocol. The out-of-band interface is accessible by either https (preference) or ssh. For default credentials please visit [[Default_credentials|Default credentials]] . Please make sure to change these default passwords and store them is a sale place. | |||
| |||
=== Changing the IP configuration === | |||
| |||
| |||
| |||
|
Revision as of 12:27, 16 January 2022
Introduction
COMCERT PMA-2XX is a custom-build appliance optimized for running NETSCOUT InfiniStream. This guide will assist you in configuring the appliance for first use.
Solution
Physical installation and connections
Please visit PMA-2XX Physical installation, connections and environmental specifications for detailed information on how to install the appliance and connect it to the network.
IP configuration
The appliance management (MGT) and out-of-band (iDRAC) interface comes pre configured with the following IP parameters.
Parameter | MGT | iDAC |
---|---|---|
IP address | 192.168.0.1 | 192.168.1.1 |
IP subnet mask | 255.255.255.0 | 255.255.255.0 |
Default router | 192.168.0.1 | 192.168.1.1 |
DNS Server | 192.168.0.1 | 192.168.1.1 |
Domain suffix | comcert.com | comcert.com |
NTP Server | 192.168.0.1 | 192.168.1.1 |
To access the appliance either by its management interface of out-of-band interface, use a laptop with a static IP address in the same IP subnet as the respective interface and a standard four-pair twisted-pair cable. The management interface is only accessible using the ssh protocol. The out-of-band interface is accessible by either https (preference) or ssh. For default credentials please visit Default credentials . Please make sure to change these default passwords and store them is a sale place.